Comparison of single radial immunodiffusion and ELISA for the quantification of immunoglobulin G in bovine colostrum, milk and calf sera
dc.contributor.author | Dunn, Amanda | |
dc.contributor.author | Duffy, Catherine | |
dc.contributor.author | Gordon, Alan | |
dc.contributor.author | Morrison, Steven | |
dc.contributor.author | Argűello, Anastasio | |
dc.contributor.author | Welsh, Michael | |
dc.contributor.author | Earley, Bernadette | |
dc.date.accessioned | 2021-06-14T14:11:42Z | |
dc.date.available | 2021-06-14T14:11:42Z | |
dc.date.issued | 2017-11-02 | |
dc.description | Publication history: Accepted - 12 October 2017; Published online - 02 November 2017. | en_US |
dc.description.abstract | The overall objective was to compare immunoglobulin G (IgG) concentrations measured by single radial immunodiffusion (sRID) and ELISA-based methods in samples of bovine colostrum and transition milk from contrasting breed types (Limousin × Friesian (n = 10) and Holstein (n = 10)). Jugular blood samples were collected at 48 h post-birth from beef (n = 10) and dairy (n = 10) calves and sera harvested subsequent to colostrum consumption. Absolute colostrum IgG values determined by ELISA showed poor agreement with mean (SD) IgG values measured using sRID, fixed bias (sRID – ELISA) was 31.89 (±9.84) mg/mL; having wide limits of agreement (12.61–51.17) and a low concordance coefficient (0.26). The agreement between ELISA and sRID when measuring serum IgG was greater than that of colostrum, fixed bias (sRID – ELISA) was 12.36 (±6.60) mg/mL; having narrower limits of agreement (−0.58 to 25.30) and serum IgG concentrations had a greater concordance coefficient (0.44) between samples. Calf sera IgG measured using the indirect zinc sulphate turbidity test showed a strong correlation with the sRID and ELISA methods (P < .001), R2 = 0.78 and R2 = 0.77 respectively. Overall, the ELISA and sRID methodologies had a strong positive association with almost a twofold (1.8) difference between values; therefore, they provide diverse absolute values of IgG concentration. | en_US |
dc.identifier | http://hdl.handle.net/20.500.12518/281 | |
dc.identifier.citation | Dunn, A., Duffy, C., Gordon, A., Morrison, S., Argűello, A., Welsh, M. and Earley, B. (2017) ‘Comparison of single radial immunodiffusion and ELISA for the quantification of immunoglobulin G in bovine colostrum, milk and calf sera’, Journal of Applied Animal Research, 46(1), pp. 758–765. doi: 10.1080/09712119.2017.1394860. | en_US |
dc.identifier.issn | 0971-2119 | |
dc.identifier.uri | https://doi.org/10.1080/09712119.2017.1394860 | |
dc.language.iso | en | en_US |
dc.publisher | Taylor & Francis | en_US |
dc.rights | © 2017 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. | en_US |
dc.subject | ELISA | en_US |
dc.subject | single radial immunodiffusion | en_US |
dc.subject | zinc sulphate turbidity test | en_US |
dc.subject | Brix refractometer | en_US |
dc.subject | IgG | en_US |
dc.subject | calf | en_US |
dc.subject | colostrum | en_US |
dc.title | Comparison of single radial immunodiffusion and ELISA for the quantification of immunoglobulin G in bovine colostrum, milk and calf sera | en_US |
dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Comparison of single radial immunodiffusion and ELISA for the quantification of immunoglobulin G in bovine colostrum milk and calf sera.pdf
- Size:
- 1.54 MB
- Format:
- Adobe Portable Document Format
- Description:
- Final published version